What's New in SACS 5.1 updates:

 

Post Processor Module Version 5.1.05   5/31/02 

  1. Removed debug print for NPD and Norsok codes.

  2. Reports rings as ‘Failed in ring design’ if the number of iterations is exceeded before a suitable ring thickness is determined.

  3. Fixed program so that when using an angle cross section from the library file the program attaches the vertical leg to the plate by default instead of the horizontal leg.

  4. Fixed program so that it does not terminate when redesigning and the FILE option is not selected and the GRUPs refer to a MEMBER library file.

  5. Program now passes model pointer information to the Postvue database which allows the program to launch more quickly.

  6. Added Solid element stress detail report to the table of contents.

  7. Added unity check detail report for solid and shell elements.

  8. Implemented local buckling factor Qs for WF section.